Chapter 3 Building Physical Diagrams
Applying and enabling a sequence on a column
To apply and enable a sequence on a column:
- Select Model→Columns to display the List of Columns.
- Click a column to which you want to apply a sequence.
An arrow appears at the beginning of the line.
- Double-click the arrow at the beginning of the line.
or
Click the Properties tool.
The Column Property sheet opens to the General page.
- Select a sequence from the Sequence dropdown listbox.
- Click OK in each of the dialog boxes.
You have applied the sequence to the column.
- Select Tools→Rebuild Objects→Rebuild Triggers to display the Rebuild Triggers dialog box.
- Click the Selection tab to display the Selection page.
- Select the table containing the column to which you want to attach a sequence, and deselect the tables to which you do not want to attach a sequence.
- Click OK.
The triggers are rebuilt and the sequence is enabled on the column.
For more information on rebuilding triggers, see the Building Triggers and Procedures chapter.
|