Storage Checks (PDM)

The following PDM model checks are made on storages:

Check

Description and Correction

Storage name and code uniqueness

Storage names and codes must be unique in the model.

Manual correction: Modify the duplicate name/code

Automatic correction: Appends a number to the duplicate name/code

Storage code maximum length

The code of the storage is longer than the maximum allowed by the DBMS.

Manual correction: Reduce the length of the code

Automatic correction: Reduces the code to a permissible length

Storage not used

The storage you have created is not used in the model.

Manual correction: Delete the storage or apply the storage as a physical option to a table, an index, a key, a column, a tablespace or a view (Options tab of the object property sheet)

Automatic correction: None


Created October 7, 2009. Send feedback on this help topic to Sybase Technical Publications: pubs@sybase.com