Default Checks (PDM)

The following PDM model checks are made on defaults:

Check

Description and Correction

Default name and code uniqueness

Default names and codes must be unique in the model.

Manual correction: Modify the duplicate name/code

Automatic correction: Appends a number to the duplicate name/code

Default code maximum length

The default code length is limited by the maximum length specified in the DBMS definition (MaxLen entry, in the Objects > Default category ).

Manual correction: Modify the default code length to meet this requirement

Automatic correction: Truncates the default code length to the maximum length specified in the DBMS definition

Default value empty

You must type a value for the default, this value is used during generation.

Manual correction: Type a value in the Value box of the default property sheet

Automatic correction: None

Several defaults with same value

A model should not contain several defaults with identical value.

Manual correction: Modify default value or delete defaults with identical value

Automatic correction: None