Date parsing  Error message thrown by EPEEngine

Release Bulletin New Era of Networks Process Server Version 3.6.1 for Solaris, Windows NT/2000, AIX, HP

Parsing NCM messages

Issue #: 265474

Problem: When Process Server uses the NDO-NCF to parse NCF messages (NCMPrefix and NCMRepositoryDir are set in nnsyreg.dat), a bogus error message is generated saying that the NCM file could not be found. However, the NCM file is found later in the search process and therefore, there should be no error.

The search for the file is based on current structure for the name and location of the .ncm file (as specified by the NNRepositoryDir and NCMPrefix values in the nnsyreg.dat file.) The parser therefore uses the following structure to locate the file:

NNRepositoryDir/NCMPrefix/<object>.ncm

Since few files have been created at this time using this configuration specification, the parser also looks for the file based on the following information:

NNRepositoryDir/NCMPrefix/<Prefix>.IC.<object>.ncm

Workaround: Ignore the error messages. Begin updating from the previous naming conventions for.ncm files to the current naming convention.





Copyright © 2002. Sybase Inc. All rights reserved. Error message thrown by EPEEngine

View this release bulletin as PDF