[CR #401336] if you have a equi-join clause between two different length char() and char()/varchar() type columns and also use char_length() on one of the columns, the result of the char_length() is indeterminate. For example:
create table t1 (sid char(8), styp char(5)) go create table t2 (sid char(16)) go select char_length(a.sid) from t1 a, t2 b where a.sid=b.sid and styp = 'R1' go
Workaround: Use convert() in char_length() to state explicitly which type you need for the char_length.
For example, in the above query, use:
select char_length(convert(char(8), a.sid)) from t1 a, t2 b where a.sid=b.sid and styp = 'R1'
The same is true for binary() and varbinary() with data_length(), unichar() and univarchar() with char_length().