You can enter envelope values for these parameters:
The Interchange code and qualifier is the default sender code and qualifier on outbound messages.
For outbound X12 messages, the code and qualifier are the Interchange Sender Code/Qualifier on the ISA segment.
For outbound EDIFACT messages, the code is the Interchange Sender Identification on the UNB address.
For outbound HL7 messages, the code is the Sending Facility on the MSH segment, the File Sending Facility on the FHS segment, or the Batch Sending Facility on the BHS segment.
The Interchange Internal ID and Interchange Internal Sub-ID codes (EDIFACT only).
The Group code and qualifier is used on EDI group-level inner envelopes as the default sender code on outbound messages.
For outbound X12 messages, this is the Application Sender code on the GS segment.
For outbound EDIFACT messages, this is the Application Sender Identification on the UNG segment.
For outbound HL7, it is the Sending Application on the MSH segment, the File Sending Application on the FHS segment, or the Batch Sending Application on the BHS segment.
The Authorization code and qualifier (X12 and EDIFACT only) is used for authentication purposes, such as user IDs.
For outbound X12 messages, the code and qualifier are the Authorization Information and Authorization Information Qualifier on the ISA segment.
For outbound EDIFACT messages, the code is the Application Password on the UNG segment.
The Security code and qualifier is used for additional authentication purposes, such as passwords. T
For outbound X12 messages, the code and qualifier are the Security Information and Security Information Qualifier on the ISA segment.
For outbound EDIFACT messages, they are the Recipient Reference/Password and Recipient Reference/Password Qualifier on the UNB segment.
For outbound HL7 messages, they are the Security on the MSH segment, the File Security on the FHS segment, or the Batch Security on the BHS segment.
Interchange, Authorization, and Security each have a Qualifier, Description, and Code. The Qualifier identifies what type of Code is used, the Description is a short explanation for that type of code, and the Code is the actual code. To select these values:
Selecting outbound sender default values
Right-click the Interchange Qualifier text box
The INTERCHANGE SELECTION window displays, listing all the possible interchange qualifiers.
Choose a qualifier and select OK.
Right-click the Authorization Qualifier text box
The AUTHORITY SELECTION window displays
Choose a qualifier and select OK.
Right-click the Security Qualifier text box.
The SECURITY SELECTION window displays, with two (2) options:
00 No Security Information Present
01 Present
Choose a qualifier and select OK.