Number
|
Severity
|
Text and Explanation
|
1301
|
16
|
The Propagation Context Data entry could not be saved. There is already an entry with the same key values for the context provided.
Explanation: Adaptive Server could not perform the requested action. Check
your command for missing or incorrect database objects, variable
names, and/or input data.
|
1302
|
16
|
A Propagation Context Data value could not be returned in parameter %d because the datatype of the return parameter does not match the datatype of the stored field.
Explanation: Command failed. Check the syntax of the SQL statement calling
the system function.
|
1303
|
16
|
The second argument for this Propagation Context Data built-in command specifies the number of keys supplied with the call. This argument must be of datatype `integer'.
Explanation: Command failed. Check the syntax of the SQL statement calling
the system function.
|
1304
|
16
|
This Propagation Context Data built-in function requires at least %d arguments.
Explanation: Command failed. Check the arguments of the SQL statement
calling the system function.
|
1305
|
16
|
This Propagation Context Data built-in function requires one argument.
Explanation: Command failed. Check the arguments of the SQL statement
calling the system function.
|
1306
|
16
|
The second argument for this Propagation Context Data built-in command specifies the number of keys supplied with the call. The value `%d' supplied is more than the keys given. At most `%d' arguments may be keys for this call.
Explanation: Command failed due to invalid or illegal request. Check syntax, semantics,
and permissions. Take any corrective action indicated by message.
|
1307
|
18
|
Internal Error in Propagation Context routines: An invalid or garbaged command 0x%x was seen by pcxt__cmdinit().
Explanation: Command failed due to internal Adaptive Server problem. Perform
any diagnostic action indicated by message. Report the error to
your System Administrator.
|
1308
|
18
|
Internal Error in Propagation Context routines: pcxt__nodenew(PCXT_NODE_ENTRY) copied %d arguments, expected %d arguments.
Explanation: Command failed due to internal Adaptive Server problem. Perform
any diagnostic action indicated by message. Report the error to
your System Administrator.
|
1309
|
18
|
Internal Error in Propagation Context routines: An invalid or garbaged node type 0x%x tried to free memory at 0x%x in pcxt__nodefree(). The request was ignored.
Explanation: Command failed due to internal Adaptive Server problem. Perform
any diagnostic action indicated by message. Report the error to
your System Administrator.
|
1310
|
18
|
Internal Error in Propagation Context routines: The memory tracking fields in the PCD resource structure are inconsistent: inuse %d, free %d. Some PCD memory may not be reclaimed until the login session ends.
Explanation: Command failed due to internal Adaptive Server problem. Perform
any diagnostic action indicated by message. Report the error to
your System Administrator.
|
1311
|
18
|
Internal Error in Propagation Context routines: An invalid or garbaged node type 0x%x was seen by pcxt__nodedup().
Explanation: Command failed due to internal Adaptive Server problem. Perform
any diagnostic action indicated by message. Report the error to
your System Administrator.
|
1312
|
18
|
Internal Error in Propagation Context routines: An invalid or garbaged node type 0x%x was seen by pcxt__nodenew().
Explanation: Command failed due to internal Adaptive Server problem. Perform
any diagnostic action indicated by message. Report the error to
your System Administrator.
|
1313
|
18
|
Internal Error in Propagation Context routines: An invalid or garbaged event type 0x%x was seen by pcxt_event().
Explanation: Command failed due to internal Adaptive Server problem. Perform
any diagnostic action indicated by message. Report the error to
your System Administrator.
|
1314
|
16
|
The built-in function requested %d data fields as return parameters. The Propagation Context Data entry that was selected contains only %d data fields. It is an error to request more data fields than exist in the entry.
Explanation: Command failed due to invalid or illegal request. Check syntax, semantics,
and permissions. Take any corrective action indicated by message.
|
1315
|
16
|
Argument %d of this Propagation Context Data built-in command must be of datatype `integer'.
Explanation: Command failed due to invalid or illegal request. Check syntax, semantics,
and permissions. Take any corrective action indicated by message.
|
1316
|
10
|
Context Name is (%.*s)
Explanation: This is an informational message.
|
1317
|
10
|
Attribute Name (%.*s) Value (%.*s)
Explanation: This is an informational message.
|
1318
|
16
|
Attributes in SYS_SESSION cannot be set.
Explanation: This is an informational message.
|