This section contains error messages for the Adaptive Server Site Buffer Manager.
26
Could not get the address lock. address=0x%1x, status=%d.
Address locks control memory addresses. They are used for:
Object Allocation Map (OAM) pages
Allocation pages
Updating the disk maps in the database table memory structure
Updating values for descriptors and site buffers
The Site Buffer Manager is one of the managers that control Server-to-Server communications.
Error 8704 occurs when the Site Buffer Manager fails to get an address lock for an active site buffer and fails to attach a logical connection to it.
This error is caused by an Adaptive Server problem.
Shut down and restart Adaptive Server.
If the 8704 error persists, call Sybase Technical Support.
Have the following information available before calling Sybase Technical Support:
Server version and SWR version level
Server error log
Text of all error messages
sp_configure, sp_who, and dbcc lock output
All versions